Description
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Need help?
This complete fire door kit is perfect for HMO’s, Office, Public spaces where you need a fire door that can be operated using lever handles from either side. This also includes a double cylinder and keys. Which allows you to lock the door from either side using a key. This kit is ideal for corridors, passageways or office doors that can be locked. These kits have been purpose designed for either use on timber doors. All products have been tested and are in accordance with fire ratings of at least up to 60 minutes for a timber doors.
Timber Door Kit
1no - Door Closure - Briton 131 door closure, regular duty, Size 2-4, silver
1no – lever handle set - 19mm diameter levers, 53x8mm sprung rose, 4-point fixing point, grade 304 satin stainless steel, c/w screw and bolt through fixings.
3no - Hinges - Ball Bearing Hinge, Grade 13, Plain, Grade 304,102mm x 76mm 3mm, Non-Branded, Wood screws.
1no - Hinges Pads Pack - 101 x 30mm hinge pad to suit 102 x 76mm hinge, pack of 6no.
1no - Fire Exit Disc - FIRE DOOR KEEP SHUT SIGN, 76mm x 1.2mm thick, Blue & Natural, Drilled & Countersunk, bagged with 2 screws.
1no - Mini Teardrop Seal 7.5m coil- Mini silicone teardrop seal, 4.5mm thick x 10mm wide x 7.5 metre coil, self-adhesive backing.
1no – Mortice Sash lock Case, 20mm Radius Forends, 60mm back set.
1no – Lockcase Pads - Intumescent lock pack, 4-part to suit DIN standard lock case with 60mm backset.
1no – Cylinder – Euro Double cylinder, 70mm cylinder. Operated by key either side, supplied with 3 keys.
1no – Pair Escutcheon - Euro escutcheon, 53 x 4mm, stainless steel inner.
Timber Fire Rated
131-SES – Door closer tested to BS EN 1634-1:2000 2 hours on timber doors. Certifire approved No CF 5512 CE and ARCA marked to EN 1154-1996
Lever Handle set – Fire assessed for integrity use on insulated timber door sets for a duration up to 60 minutes, in accordance with BS EN 1364-1.
Hinges – Suitable for use on Timber fire doors up to 60 minutes, tested to EN1634-1.
Hinge Pads – Use FS4004 type intumescent can be fitted to insulated timber sets to provide up to 60 minutes integrity tested in accordance with BS EN 1634-1:2000.
Fire exit sign – Fire Exit Signs can be screwed fixed. Can be used without affecting the fire rating of a door.
Mini teardrop – Can be included on insulated timber doors without detracting from their achieved fire performance to BS 476:22:1987. Suitable for use on timber doors up to 60 minutes. Also tested to BS EN1634-1 and 1634-3 for smoke and fire testing.
Lockcase – Manufactured in accordance with DIN 18251 and CE marked. Tested to BS EN 1364-1:2000. Timber insulated doors for up to 60 minutes.
Lockcase Intumescent – Use FS4004 type intumescent can be fitted to insulated timber sets to provide up to 60 minutes integrity tested in accordance with BS EN 1634-1:2000.
Escutcheons – Assessed for integrity use on insulated timber doorsets for up to 60 minutes doorsets in accordance with BS EN 1634-1:2000.
Cylinders – Fire tested to 60 minutes, FD30/60.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Over 6,000 lines
Thousands of products to choose from
Secure Online Payments
Payments are secured by 256-bit SSL encryption
Fast Delivery
Usually next working day if ordered before 3 p.m.
Outstanding Support
Contact us by phone, by email, or face to face